  • This paper aims to contribute to the classification and specification of glass fiber reinforced concrete (GFRC) and to deal with the question if structural glass fiber reinforced concrete as a special kind of glass fiber reinforced concrete is suited for use in load-bearing members. Despite excellent material properties, the use of glass fibers in a concrete matrix is carried out so far only in non- structural elements or as a modification for the prevention of shrinkage cracks. The aim of re- search at the University of Applied Sciences in Leipzig is the use of alkali-resistant macro glass fibers as concrete reinforcement in structural elements as an alternative to steel fiber reinforcement. Slabs on ground, as an example for structural members, provide a sensible application for the new material because they can be casted as load bearing and non-load bearing and are mostly made of steel fiber reinforced concrete. In the future, structural glass fiber reinforced concrete shall provide a simple and visually appealing alternative to conventional steel bar or steel fiber reinforced concrete. The glass fibers can also be used in combination with conventional reinforcing bars or mat reinforcements. Initial investigations have announced some potential.

  • KEYWORDS
  • Glass Fiber Reinforced Concrete, GFRC, Slab on Ground, Structural Concrete, Bending Test
  • References
  • [1]
    Fachvereinigung Faserbetone e.V. (2013)
    http://www.fvf-faserbeton.de/
    [2]
    Deutscher Ausschuss für Stahlbeton (DAfStb) (2010) Richtlinie “Stahlfaserbeton”. Erg?nzung zu DIN 1045, M?rz 2010.
    [3]
    Falkner, H. and Teutsch, M. (2006) Stahlfaserbeton—Anwendungen und Richtlinie. In: Betonkalender, Ernst & Sohn Verlag, Berlin, 667-703.
    [4]
    (1998) DIN EN 1170-5 Precast Concrete Products—Test Method for Glass-Fibre Reinforced Cement—Part 5: Measuring Bending Strength. Complete Bending Test Method, German Version.
    [5]
    Schorn, H. (2010) Fiber Reinforced Concretes for Load Bearing Structures. (German) Verlag Bau + Technik GmbH, Düsseldorf.
    [6]
    (2007) EN 14651:2005 + A1:2007 Test Method for Metallic Fibre Concrete—Measuring the Flexural Tensile Strength (Limit or Proportionality (LOP), Residual), German Version.
    [7]
    (2009) EN 12350-5:2009: Testing Fresh Concrete—Part 5: Flow Table Test, German Version.
    [8]
    Holschemacher, K., Klug, Y. and Dehn, F. (2011) Grundlagen des Faserbetons. In: Betonkalender 2011, Ernst & Sohn Verlag, Berlin, 21-88.
    [9]
    (1998) DIN EN 1170 Precast Concrete Products—Test Method for Glass-Fibre Reinforced Cement.

Engineering Information Institute is the member of/source content provider to

http://www.scirp.org http://www.hanspub.org/ http://www.crossref.org/index.html http://www.oalib.com/ http://www.ebscohost.com/ http://www.proquest.co.uk/en-UK/aboutus/default.shtml http://ip-science.thomsonreuters.com/cgi-bin/jrnlst/jlresults.cgi?PC=MASTER&Full=journal%20of%20Bioequivalence%20%26%20Bioavailability http://publishers.indexcopernicus.com/index.php