[1]
Lee, B., Choi, W.Y. and Walker, J.K. (2000) Polymer-Polymer Miscibility Study for Plastic Gradient Index Optical Fiber. Polymer Engineering & Science, 40, 1996-1999.
http://dx.doi.org/10.1002/pen.11331
[2]
Arnfield, M.R., Gaballa, H.E., Zwicker, R.D., Islam, Q. and Schmidt-Ullrich, R. (1996) Radiation-Induced Light in Optical Fibers and Plastic Scintillators: Application to Brachytherapy Dosimetry. IEEE Transactions on Nuclear, 43, 2077-2084.
http://dx.doi.org/10.1109/23.502302
[3]
Han, K.T., Yoo, W.J., Shin, S.H., Jeon, D., Park, J.Y., Park, B.G. and Lee, B. (2012) Development of Fiber-Optic Radiation Sensor Using LYSO Scintillator for Gamma-Ray Spectroscopy. Journal of Sensor Science and Technology, 21, 287-292.
http://dx.doi.org/10.5369/JSST.2012.21.4.287
[4]
Bartesaghi, G., Conti, V., Prest, M., Mascagna, V., Scazzi, S., Cappelletti, P., Frigerio, M., Gelosa, S., Monti, A., Ostinelli, A., Mozzanica, A., Bevilacqua, R., Giannini, G., Totaro, P. and Vallazza, E. (2007) A Scintillating Fiber Dosimeter for Radiotherapy. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 581, 80-83.
http://dx.doi.org/10.1016/j.nima.2007.07.032
[5]
Becks, K.-H., Drees, J., Goldmann, K., Gregor, I.M. and Heintz, M. (2000) A Multi Channel Dosimeter Based on Scintillating Fibers for Medical Applications. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 454, 147-151.
http://dx.doi.org/10.1016/S0168-9002(00)00817-2
[6]
Jursinic, P.A. (2007) Characterization of Optically Stimulated Luminescent Dosimeters, OSLDs, for Clinical Dosimetric Measurements. Medical Physics, 34, 4594-4604.
http://dx.doi.org/10.1118/1.2804555
[7]
Jang, K.W., Shin, S.H., Kim, S.G., Kim, J.S., Yoo, W.J., Ji, Y.H. and Lee, B. (2014) Measurement of Cerenkov Radiation Induced by the Gamma-Rays of Co-60 Therapy Units Using Wavelength Shifting Fiber. Sensors, 14, 7013-7025.
http://dx.doi.org/10.3390/s140407013
[8]
Shin, S.H., Jeon, D., Kim, J.S., Jang, J.S., Jang, K.W., Yoo, W.J., Moon, J.H., Park, B.G., Kim, S. and Lee, B. (2014) Measurements of Longitudinal Gamma Ray Distribution Using a Multichannel Fiber-Optic Cerenkov Radiation Sensor. Measurement Science and Technology, 25, 114003-114008.
http://dx.doi.org/10.1088/0957-0233/25/11/114003
[9]
Soylu, H.M., Yurt Lambrecht, F. and Ers?z, O.A. (2015) Gamma Radiation Shielding Efficiency of a New Lead-Free Composite Material. Journal of Radioanalytical and Nuclear Chemistry, 305, 529-534.
http://dx.doi.org/10.1007/s10967-015-4051-3
[10]
Beddar, A.S., Mackie, T.R. and Attix, F.H. (1992) Water-Equivalent Plastic Scin-tillation Detectors for High-Energy Beam Dosimetry: I. Physical Characteristics and Theoretical Considerations. Physics in Medicine and Biology, 37, 1883-1900.
http://dx.doi.org/10.1088/0031-9155/37/10/006